-40%

Universal Hot Surface Igniter Kit, 120 Volt Nitride, FLAT, Glo-Stix Igniter,

$ 26.97

Availability: 100 in stock

Description

Gregoriou Brothers Refrigeration Since 1979
Frosty-Freeze
Universal Hot Surface Igniter Kit, 120 Volt Nitride, FLAT, Glo-Stix Igniter,
Universal Flat Igniter part no. HSIURK120vF
Universal Hot Surface Igniter Kit
120 Volt
Nitride
Glo-Stix Igniter
Good for;
Furnace's
Boiler's
Pool's
Water Heater's
Cloths Dryer's
Silicon Nitride heating element
Bracket passive plated mild steel
Ceramic insulator body glazed 95% alumina - glazed finish
Cable - PTFE - U/L Specification - temperature rating 250°C
Specification
Time to 1200¼C
> 12 seconds @ 120 volt
Current
3.3-4.2 amps
Operating Voltage
120 volts +10% -15%
Power Rating
400-500 watts
Over time many part numbers for igniters have been generated, most refer to the same igniter, but with the modification of extra lead lengths and so on.
All igniters fit into a burner housing that has only a few variations.
Therefore the universal bracket kit can be used in a simple series of combinations to replace over 130 types of the most commonly used hot surface igniter.
Fitting Instructions
Please read all these instructions to the end carefully before beginning installation.
1. Identify which type of hot surface igniter is inside your appliance.
2. Unplug your existing igniter, retaining all fittings, and match it up with diagrams above (this can also be done by comparing the top end view of the base type).
3. Compare the position of the ridge on your existing igniter carefully to the top view diagram. Ensure that you have the correct igniter type. Take your time to identify this carefully.
4. Referring to the centre bottom diagram, break off the tabs indicated, preferably with thin nose pliers.
5. Cut off the plug from your appliance, as close to the plug as possible. Make sure there is enough lead to work with. Bare one quarter of an inch of wire.
6. Fit the universal adaptor to the appliance using existing screws. Once the universal adaptor is fitted, screw the igniter into the adaptor, as per the final diagram, using the screw provided.
7. Attach the wires from the appliance onto the igniter, by twisting the bared ends together, matching one wire from the igniter, to one wire from the controller (please refer to diagram).
8. Finally, take the terminal caps provided and screw down tight over the joined bare wires, ensuring that no bare wires are showing. If necessary, the igniter wires can be cut to length.
9.Check installation is secure and safe, routing leads away from the burner.
Commissioning
1. Turn on the gas supply and electrical supply to the appliance.
2. Set the room thermostat for heat.
3. Test furnace for proper ignition and operation.
4. Verify that the Power-On LED, on the power module, is on during the Glo-Stix&; igniter warm-up.
5. During igniter warm-up, using a true RMS voltmeter, measure the voltage across the igniter. Voltage should be between 50 VAC and 120 VAC.
6. Make sure the Glo-Stix&; igniter does not remain energized in the flame for more than a few seconds.
7. Replace the burner compartment door.
8. Place Glo-Stix&; upgrade label on front of the appliance, write the date of installation and your contact details.
American Road
Equip
201W
Acro Air
1096048
|
1380680
Armstrong Air
38322B001
Carrier Corporation
LH33ZS001A
|
LH33ZS002
Claire Brothers
C-238
|
C-242
Coleman
1474-051
|
1474-052
Comfort Maker
1096048
Detroit
Radiant
201D
DMO Industries
20834
Dornback Furnace
271W
Ducane
20015201
Enerco Tech
10399
Evcon
1474-051
|
1474-052
Goodman
B10401009
Heil
1096048
Hupp Industries
09050
Intercity
1009604
|
1096048
Majestic
75-92-104
|
75-92-105
Metzger
201N
|
201W
Mor-Flo
3200618
Nordyne
105141000
|
632-0770
|
632-0880
|
902661
902694
|
903110
|
FC007
Norton
201
|
201D
|
201K
|
201L
|
201R
|
201W
|
271
271D
|
271M
|
271N
|
271NM
|
271P
|
271W
Raypak
600915
Rheem
62-22441-01
|
62-22868-82
|
62-22868-93
Roberts Gordon
90434300
|
90436600
Robertshaw
41-402
|
41-403
|
41-404
|
41-405
|
41-407
41-408
|
41-409
|
41-410
|
41-411
|
41-412
41-414
Smith HB
50018
Snyder General
1380654
|
1380672
|
1380680
Superior Fireplace
94851
Tempstar
1096048
|
1148245
Trane Company
340039P01
|
B138196P01
|
B144676P01
B144676P02
|
B340039P01
|
IGN21
IGN23
|
IGN26
|
IGN30
Viessman
9302-094
Wayne
Home
Equip
62821-001
|
62821-002
Weil McLain
511-330-139
|
511-330-190
|
511-330-193
White LB Company
120-07549
White-Rodgers
767A-301
|
767A-303
|
767A-306
|
767A-310
767A-311
|
767A-350
|
767A-353
|
767A-354
767A-357
|
767A-361
|
767A-364
|
767A-365
767A-366
|
F767A-357
|
F767A-361
F767A-365
|
F767A-366
Williamson
09050
York
International
025-27766-000
|
025-27774-000
025-29043-000
|
025-29050-000
025-32625-000
|
025-32626-000
025-33421-000
|
373-05342-700
473-12509-001
no. HSIURK120v
$Universal Flat Igniter part no. HSIURK120vF Universal Hot Surface Igniter Kit 120 Volt Nitride Glo-Stix Igniter Good for; Furnace's Boiler's Pool's Water Heater's Cloths Dryer's Silicon Nitride heating element Bracket passive plated mild steel Ceramic insulator body glazed 95% alumina - glazed finish Cable - PTFE - U/L Specification - temperature rating 250°C Specification Time to 1200¼C > 12 seconds @ 120 volt Current 3.3-4.2 amps Operating Voltage 120 volts +10% -15% Power Rating 400-500 watts Over time many part numbers for igniters have been generated, most refer to the same igniter, but with the modification of extra lead lengths and so on. All igniters fit into a burner housing that has only a few variations. Therefore the universal bracket kit can be used in a simple series of combinations to replace over 130 types of the most commonly used hot surface igniter. Fitting Instructions Please read all these instructions to the end carefully before beginning installation. 1. Identify which type of hot surface igniter is inside your appliance. 2. Unplug your existing igniter, retaining all fittings, and match it up with diagrams above (this can also be done by comparing the top end view of the base type). 3. Compare the position of the ridge on your existing igniter carefully to the top view diagram. Ensure that you have the correct igniter type. Take your time to identify this carefully. 4. Referring to the centre bottom diagram, break off the tabs indicated, preferably with thin nose pliers. 5. Cut off the plug from your appliance, as close to the plug as possible. Make sure there is enough lead to work with. Bare one quarter of an inch of wire. 6. Fit the universal adaptor to the appliance using existing screws. Once the universal adaptor is fitted, screw the igniter into the adaptor, as per the final diagram, using the screw provided. 7. Attach the wires from the appliance onto the igniter, by twisting the bared ends together, matching one wire from the igniter, to one wire from the controller (please refer to diagram). 8. Finally, take the terminal caps provided and screw down tight over the joined bare wires, ensuring that no bare wires are showing. If necessary, the igniter wires can be cut to length. 9.Check installation is secure and safe, routing leads away from the burner. Commissioning 1. Turn on the gas supply and electrical supply to the appliance. 2. Set the room thermostat for heat. 3. Test furnace for proper ignition and operation. 4. Verify that the Power-On LED, on the power module, is on during the Glo-Stix&; igniter warm-up. 5. During igniter warm-up, using a true RMS voltmeter, measure the voltage across the igniter. Voltage should be between 50 VAC and 120 VAC. 6. Make sure the Glo-Stix&; igniter does not remain energized in the flame for more than a few seconds. 7. Replace the burner compartment door. 8. Place Glo-Stix&; upgrade label on front of the appliance, write the date of installation and your contact details. American Road Equip 201W Acro Air 1096048 | 1380680 Armstrong Air 38322B001 Carrier Corporation LH33ZS001A | LH33ZS002 Claire Brothers C-238 | C-242 Coleman 1474-051 | 1474-052 Comfort Maker 1096048 Detroit Radiant 201D DMO Industries 20834 Dornback Furnace 271W Ducane 20015201 Enerco Tech 10399 Evcon 1474-051 | 1474-052 Goodman B10401009 Heil 1096048 Hupp Industries 09050 Intercity 1009604 | 1096048 Majestic 75-92-104 | 75-92-105 Metzger 201N | 201W Mor-Flo 3200618 Nordyne 105141000 | 632-0770 | 632-0880 | 902661 902694 | 903110 | FC007 Norton 201 | 201D | 201K | 201L | 201R | 201W | 271 271D | 271M | 271N | 271NM | 271P | 271W Raypak 600915 Rheem 62-22441-01 | 62-22868-82 | 62-22868-93 Roberts Gordon 90434300 | 90436600 Robertshaw 41-402 | 41-403 | 41-404 | 41-405 | 41-407 41-408 | 41-409 | 41-410 | 41-411 | 41-412 41-414 Smith HB 50018 Snyder General 1380654 | 1380672 | 1380680 Superior Fireplace 94851 Tempstar 1096048 | 1148245 Trane Company 340039P01 | B138196P01 | B144676P01 B144676P02 | B340039P01 | IGN21 IGN23 | IGN26 | IGN30 Viessman 9302-094 Wayne Home Equip 62821-001 | 62821-002 Weil McLain 511-330-139 | 511-330-190 | 511-330-193 White LB Company 120-07549 White-Rodgers 767A-301 | 767A-303 | 767A-306 | 767A-310 767A-311 | 767A-350 | 767A-353 | 767A-354 767A-357 | 767A-361 | 767A-364 | 767A-365 767A-366 | F767A-357 | F767A-361 F767A-365 | F767A-366 Williamson 09050 York International 025-27766-000 | 025-27774-000 025-29043-000 | 025-29050-000 025-32625-000 | 025-32626-000 025-33421-000 | 373-05342-700 473-12509-001 no. HSIURK120v
Gregoriou Brothers Refrigeration Since 1979
Frosty-Freeze
Universal Hot Surface Igniter Kit, 120 Volt Nitride, FLAT, Glo-Stix Igniter,
Universal Flat Igniter part no. HSIURK120vF
Universal Hot Surface Igniter Kit
120 Volt
Nitride
Glo-Stix Igniter
Good for;
Furnace's
Boiler's
Pool's
Water Heater's
Cloths Dryer's
Silicon Nitride heating element
Bracket passive plated mild steel
Ceramic insulator body glazed 95% alumina - glazed finish
Cable - PTFE - U/L Specification - temperature rating 250°C
Specification
Time to 1200¼C
> 12 seconds @ 120 volt
Current
3.3-4.2 amps
Operating Voltage
120 volts +10% -15%
Power Rating
400-500 watts
Over time many part numbers for igniters have been generated, most refer to the same igniter, but with the modification of extra lead lengths and so on.
All igniters fit into a burner housing that has only a few variations.
Therefore the universal bracket kit can be used in a simple series of combinations to replace over 130 types of the most commonly used hot surface igniter.
Fitting Instructions
Please read all these instructions to the end carefully before beginning installation.
1. Identify which type of hot surface igniter is inside your appliance.
2. Unplug your existing igniter, retaining all fittings, and match it up with diagrams above (this can also be done by comparing the top end view of the base type).
3. Compare the position of the ridge on your existing igniter carefully to the top view diagram. Ensure that you have the correct igniter type. Take your time to identify this carefully.
4. Referring to the centre bottom diagram, break off the tabs indicated, preferably with thin nose pliers.
5. Cut off the plug from your appliance, as close to the plug as possible. Make sure there is enough lead to work with. Bare one quarter of an inch of wire.
6. Fit the universal adaptor to the appliance using existing screws. Once the universal adaptor is fitted, screw the igniter into the adaptor, as per the final diagram, using the screw provided.
7. Attach the wires from the appliance onto the igniter, by twisting the bared ends together, matching one wire from the igniter, to one wire from the controller (please refer to diagram).
8. Finally, take the terminal caps provided and screw down tight over the joined bare wires, ensuring that no bare wires are showing. If necessary, the igniter wires can be cut to length.
9.Check installation is secure and safe, routing leads away from the burner.
Commissioning
1. Turn on the gas supply and electrical supply to the appliance.
2. Set the room thermostat for heat.
3. Test furnace for proper ignition and operation.
4. Verify that the Power-On LED, on the power module, is on during the Glo-Stix&; igniter warm-up.
5. During igniter warm-up, using a true RMS voltmeter, measure the voltage across the igniter. Voltage should be between 50 VAC and 120 VAC.
6. Make sure the Glo-Stix&; igniter does not remain energized in the flame for more than a few seconds.
7. Replace the burner compartment door.
8. Place Glo-Stix&; upgrade label on front of the appliance, write the date of installation and your contact details.
American Road
Equip
201W
Acro Air
1096048
|
1380680
Armstrong Air
38322B001
Carrier Corporation
LH33ZS001A
|
LH33ZS002
Claire Brothers
C-238
|
C-242
Coleman
1474-051
|
1474-052
Comfort Maker
1096048
Detroit
Radiant
201D
DMO Industries
20834
Dornback Furnace
271W
Ducane
20015201
Enerco Tech
10399
Evcon
1474-051
|
1474-052
Goodman
B10401009
Heil
1096048
Hupp Industries
09050
Intercity
1009604
|
1096048
Majestic
75-92-104
|
75-92-105
Metzger
201N
|
201W
Mor-Flo
3200618
Nordyne
105141000
|
632-0770
|
632-0880
|
902661
902694
|
903110
|
FC007
Norton
201
|
201D
|
201K
|
201L
|
201R
|
201W
|
271
271D
|
271M
|
271N
|
271NM
|
271P
|
271W
Raypak
600915
Rheem
62-22441-01
|
62-22868-82
|
62-22868-93
Roberts Gordon
90434300
|
90436600
Robertshaw
41-402
|
41-403
|
41-404
|
41-405
|
41-407
41-408
|
41-409
|
41-410
|
41-411
|
41-412
41-414
Smith HB
50018
Snyder General
1380654
|
1380672
|
1380680
Superior Fireplace
94851
Tempstar
1096048
|
1148245
Trane Company
340039P01
|
B138196P01
|
B144676P01
B144676P02
|
B340039P01
|
IGN21
IGN23
|
IGN26
|
IGN30
Viessman
9302-094
Wayne
Home
Equip
62821-001
|
62821-002
Weil McLain
511-330-139
|
511-330-190
|
511-330-193
White LB Company
120-07549
White-Rodgers
767A-301
|
767A-303
|
767A-306
|
767A-310
767A-311
|
767A-350
|
767A-353
|
767A-354
767A-357
|
767A-361
|
767A-364
|
767A-365
767A-366
|
F767A-357
|
F767A-361
F767A-365
|
F767A-366
Williamson
09050
York
International
025-27766-000
|
025-27774-000
025-29043-000
|
025-29050-000
025-32625-000
|
025-32626-000
025-33421-000
|
373-05342-700
473-12509-001
no. HSIURK120v
Universal Flat Igniter part no. HSIURK120vF
Universal Hot Surface Igniter Kit
120 Volt
Nitride
Glo-Stix Igniter
Good for;
Furnace's
Boiler's
Pool's
Water Heater's
Cloths Dryer's
Silicon Nitride heating element
Bracket passive plated mild steel
Ceramic insulator body glazed 95% alumina - glazed finish
Cable - PTFE - U/L Specification - temperature rating 250°C
Specification
Time to 1200¼C
> 12 seconds @ 120 volt
Current
3.3-4.2 amps
Operating Voltage
120 volts +10% -15%
Power Rating
400-500 watts
Over time many part numbers for igniters have been generated, most refer to the same igniter, but with the modification of extra lead lengths and so on.
All igniters fit into a burner housing that has only a few variations.
Therefore the universal bracket kit can be used in a simple series of combinations to replace over 130 types of the most commonly used hot surface igniter.
Fitting Instructions
Please read all these instructions to the end carefully before beginning installation.
1. Identify which type of hot surface igniter is inside your appliance.
2. Unplug your existing igniter, retaining all fittings, and match it up with diagrams above (this can also be done by comparing the top end view of the base type).
3. Compare the position of the ridge on your existing igniter carefully to the top view diagram. Ensure that you have the correct igniter type. Take your time to identify this carefully.
4. Referring to the centre bottom diagram, break off the tabs indicated, preferably with thin nose pliers.
5. Cut off the plug from your appliance, as close to the plug as possible. Make sure there is enough lead to work with. Bare one quarter of an inch of wire.
6. Fit the universal adaptor to the appliance using existing screws. Once the universal adaptor is fitted, screw the igniter into the adaptor, as per the final diagram, using the screw provided.
7. Attach the wires from the appliance onto the igniter, by twisting the bared ends together, matching one wire from the igniter, to one wire from the controller (please refer to diagram).
8. Finally, take the terminal caps provided and screw down tight over the joined bare wires, ensuring that no bare wires are showing. If necessary, the igniter wires can be cut to length.
9.Check installation is secure and safe, routing leads away from the burner.
Commissioning
1. Turn on the gas supply and electrical supply to the appliance.
2. Set the room thermostat for heat.
3. Test furnace for proper ignition and operation.
4. Verify that the Power-On LED, on the power module, is on during the Glo-Stix&; igniter warm-up.
5. During igniter warm-up, using a true RMS voltmeter, measure the voltage across the igniter. Voltage should be between 50 VAC and 120 VAC.
6. Make sure the Glo-Stix&; igniter does not remain energized in the flame for more than a few seconds.
7. Replace the burner compartment door.
8. Place Glo-Stix&; upgrade label on front of the appliance, write the date of installation and your contact details.
American Road
Equip
201W
Acro Air
1096048
|
1380680
Armstrong Air
38322B001
Carrier Corporation
LH33ZS001A
|
LH33ZS002
Claire Brothers
C-238
|
C-242
Coleman
1474-051
|
1474-052
Comfort Maker
1096048
Detroit
Radiant
201D
DMO Industries
20834
Dornback Furnace
271W
Ducane
20015201
Enerco Tech
10399
Evcon
1474-051
|
1474-052
Goodman
B10401009
Heil
1096048
Hupp Industries
09050
Intercity
1009604
|
1096048
Majestic
75-92-104
|
75-92-105
Metzger
201N
|
201W
Mor-Flo
3200618
Nordyne
105141000
|
632-0770
|
632-0880
|
902661
902694
|
903110
|
FC007
Norton
201
|
201D
|
201K
|
201L
|
201R
|
201W
|
271
271D
|
271M
|
271N
|
271NM
|
271P
|
271W
Raypak
600915
Rheem
62-22441-01
|
62-22868-82
|
62-22868-93
Roberts Gordon
90434300
|
90436600
Robertshaw
41-402
|
41-403
|
41-404
|
41-405
|
41-407
41-408
|
41-409
|
41-410
|
41-411
|
41-412
41-414
Smith HB
50018
Snyder General
1380654
|
1380672
|
1380680
Superior Fireplace
94851
Tempstar
1096048
|
1148245
Trane Company
340039P01
|
B138196P01
|
B144676P01
B144676P02
|
B340039P01
|
IGN21
IGN23
|
IGN26
|
IGN30
Viessman
9302-094
Wayne
Home
Equip
62821-001
|
62821-002
Weil McLain
511-330-139
|
511-330-190
|
511-330-193
White LB Company
120-07549
White-Rodgers
767A-301
|
767A-303
|
767A-306
|
767A-310
767A-311
|
767A-350
|
767A-353
|
767A-354
767A-357
|
767A-361
|
767A-364
|
767A-365
767A-366
|
F767A-357
|
F767A-361
F767A-365
|
F767A-366
Williamson
09050
York
International
025-27766-000
|
025-27774-000
025-29043-000
|
025-29050-000
025-32625-000
|
025-32626-000
025-33421-000
|
373-05342-700
473-12509-001
no. HSIURK120v