Detail
Operation instruction:
1. Take out the product; install the hose at the air outlet.(Note: gasket is needed, or air leakage might exist.)
2. Connect 2 cold water pipes and connect them to the water pump. (Note: the lower pipe connected to the water pump is water inlet; sinking pump is used in this product. The water pump should be immersed in water for using.)
3. Install the pressure relief v-alve screw; pressure relief v-alve screw is installed at the pressure relief hole under the hose.The blow-down v-alve is installed at the
drain outlet of the first air chamber block.
4. Immerse the water pump in water and switch on the power.
5. Connect the container need to be inflated, make sure the connection is correct.
6. Screw up the screws of the blow-down v-alve and pressure relief v-alve.
7. Switch on the power ant the machine operates. Note: when the machine is operating, the water must operate correspondingly, or the product might be damaged due to overheated, personal harm may even occur.
8. After the inflation is completed, screw of the pressure relief v-alve should be firstly loosen, then the power is to be switched off, by doing so, high pressure
air backlash caused due to sudden failure of power supply would be avoided, which could lengthen l-ifetime of the product, as well as discharge high pressure air in the machine.
Warning:
1. Please use the power supply according to the parameter table.
2. If abnormal noise occurred during the using of the product, please stop using it instantly and check the cause.
3. The product should be placed at a place that it couldn’ t be t-ouched by children.
4. Please do not use it in moist and f-lammable place.
5. Please do not modify it arbitrarily, disassembling and repair by non-technical personnel is not allowed.
6. Make sure the socket could withstand a currentgreater than 8A before using it, or the circuit might be burnt, the product might be damaged and the dangers may be caused due to overload of the socket.
7. Please do not t-ouch the head section after the machine was just being used, so as to not beburnt by high temperature.
8. Please do not leave without authorized, or the product might be damaged by increasingly rising pressure, sustained overload motor, even halt due to the operation pressure has reached but it is not turned off timely.
9. When it is used for inflating slightly larger container, the cooling water should be changed every 30 minutes, in this way, the cylinder
temperature could be better controlled.
10. The machine oil should be checked regularly, make sure the oil level is above the upper edge of the red point. If color of machine oil becomes dark and black, it should be changed in time.
Parameter
Model :
Seventh Generation Lite Edition
Power Rating :
1.8KW
Inflating Speed :
2800R/Min
Noise :
MAX 85DB
Air Flow Rate :
40-50L/MIN; 1.5-1.8CFM
Working Pressure :
100-300BAR; 1500-4500PSI
Cooling System :
Water Cooling
Compression Stage :
Two Stage
Lubrication Mode :
Splash Type
Material of Cover :
Cast Aluminum
Shout down :
Manual stop/automatic stop(for optional)
Pressure indicate :
Gauge
Filtration :
Water/oil separator
Lubricating oil :
ISO VG46 or AW 46
Air hose connection :
8mm quick connect fitting
IN THE BOX
1 x
30Mpa Electric Compressor Pump
1 x
Water Pump
2 x
Water Pipe
1 x
Hose Female
1 x
Air cock
2 x
Pressure relief screw
1 x
Wearing parts
1 x
English Manual
HOME
DETAIL
SHIPPING
ABOUT US
CONTACT US
Detail
Operation instruction:
1. Take out the product; install the hose at the air outlet.(Note: gasket is needed, or air leakage might exist.)
2. Connect 2 cold water pipes and connect them to the water pump. (Note: the lower pipe connected to the water pump is water inlet; sinking pump is used in this product. The water pump should be immersed in water for using.)
3. Install the pressure relief v-alve screw; pressure relief v-alve screw is installed at the pressure relief hole under the hose.The blow-down v-alve is installed at the
drain outlet of the first air chamber block.
4. Immerse the water pump in water and switch on the power.
5. Connect the container need to be inflated, make sure the connection is correct.
6. Screw up the screws of the blow-down v-alve and pressure relief v-alve.
7. Switch on the power ant the machine operates. Note: when the machine is operating, the water must operate correspondingly, or the product might be damaged due to overheated, personal harm may even occur.
8. After the inflation is completed, screw of the pressure relief v-alve should be firstly loosen, then the power is to be switched off, by doing so, high pressure
air backlash caused due to sudden failure of power supply would be avoided, which could lengthen l-ifetime of the product, as well as discharge high pressure air in the machine.
Warning:
1. Please use the power supply according to the parameter table.
2. If abnormal noise occurred during the using of the product, please stop using it instantly and check the cause.
3. The product should be placed at a place that it couldn’ t be t-ouched by children.
4. Please do not use it in moist and f-lammable place.
5. Please do not modify it arbitrarily, disassembling and repair by non-technical personnel is not allowed.
6. Make sure the socket could withstand a currentgreater than 8A before using it, or the circuit might be burnt, the product might be damaged and the dangers may be caused due to overload of the socket.
7. Please do not t-ouch the head section after the machine was just being used, so as to not beburnt by high temperature.
8. Please do not leave without authorized, or the product might be damaged by increasingly rising pressure, sustained overload motor, even halt due to the operation pressure has reached but it is not turned off timely.
9. When it is used for inflating slightly larger container, the cooling water should be changed every 30 minutes, in this way, the cylinder
temperature could be better controlled.
10. The machine oil should be checked regularly, make sure the oil level is above the upper edge of the red point. If color of machine oil becomes dark and black, it should be changed in time.
Parameter
Model :
Seventh Generation Lite Edition
Power Rating :
1.8KW
Inflating Speed :
2800R/Min
Noise :
MAX 85DB
Air Flow Rate :
40-50L/MIN; 1.5-1.8CFM
Working Pressure :
100-300BAR; 1500-4500PSI
Cooling System :
Water Cooling
Compression Stage :
Two Stage
Lubrication Mode :
Splash Type
Material of Cover :
Cast Aluminum
Shout down :
Manual stop/automatic stop(for optional)
Pressure indicate :
Gauge
Filtration :
Water/oil separator
Lubricating oil :
ISO VG46 or AW 46
Air hose connection :
8mm quick connect fitting
IN THE BOX
1 x
30Mpa Electric Compressor Pump
1 x
Water Pump
2 x
Water Pipe
1 x
Hose Female
1 x
Air cock
2 x
Pressure relief screw
1 x
Wearing parts
1 x
English Manual